Process updates for all VNX models
Latam Cases: (Division Latin America)
- No Customer education, unless specified
- Customer Rack, unless specified
- Block Only System, unless specified
- Block Only System, unless specified
- Default Services
- If you have any query regarding request please get back to the TC.
Services for Upgrade:
- When Configuring Block Only Solution with Total Efficiency Pack, please configure Professional Services for Security & Compliance Suite/ Events and Retention i.e.1 x #PS-PKG-IMSCU . It will not select by default.
- For VNX upgrades configure 1 x #PS-BAS-UPDAEB Service for first two DAEs and 1 x PS-BAS-DAE service required for next two DAEs triggered there after.
Promo model:
VNX2 product, a recent change adds a PROMO Model to the configuration and quote. This model is added by design whenever the configuration has a flash capacity of 15% or greater. Please leave a note stating the same and there is no option to remove it from the configuration
Quoting Procedure Default For Both New & Upgrade
VNX2 New Config Default Steps
Quoting Procedure Default For Both New & Upgrade
VNX2 New Config Default Steps
RACK: EMC Rack // For Latam Cases - Customer Rack, unless specified
System: Unified // For Latam Cases - Block Only, unless specified
Vault/Base Drive: Small drive type with lowest rpm
(For VNX5200,configure same type of data drive for Base pack which will excluding from the
requested data drives- follow it if no details provided for Base pack)
Data Mover(DM): 2 - 1 for primary & 1 for Standby
Control Station(CS): 1
Software: Total Efficiency Pack, unless specified
Services: All default including migration
Education: Default / / For Latam Cases - No default, unless specified
Hw Maintenance: 36 months premium system default
Sw Maintenance: 36 months premium in sold, , unless specified
VNX1 Upgrade Config Default Steps (To fill existing)
RACK: EMC Rack // For Latam Cases - Customer Rack, unless specified
System: Unified // For Latam Cases - Block Only, unless specified
Vault/Base & Data Drive : Small drive type with lowest rpm to fill existing with total 15 drives i.e. 1st DAE fill. Take 15 drives including both Vault/Base & Data Drives for existing.
Data Mover(DM): 2 - 1 for primary & 1 for Standby
Control Station(CS): 1
Software: No need to fill existing
Services: Check process update section
Education: No
Hw Maintenance: Co-term
Sw Maintenance: 12 months premium in sold, , unless specified
VNX2 Upgrade Config Default Steps (To fill existing)
RACK: EMC Rack // For Latam Cases - Customer Rack, unless specified
System: Unified // For Latam Cases - Block Only, unless specified
Vault/Base & Data Drive : Small drive type with lowest rpm to fill existing with total 25 drives i.e. 1st DAE fill. Take 25 drives including both Vault/Base & Data Drives for existing.
Data Mover(DM): 2 - 1 for primary & 1 for Standby
Control Station(CS): 1
Software: No need to fill existing
Services: Check process update section
Education: No
Hw Maintenance: Co-term
Sw Maintenance: 12 months premium in sold, , unless specified
Mail Summary:
System: Unified // For Latam Cases - Block Only, unless specified
Vault/Base Drive: Small drive type with lowest rpm
(For VNX5200,configure same type of data drive for Base pack which will excluding from the
requested data drives- follow it if no details provided for Base pack)
Data Mover(DM): 2 - 1 for primary & 1 for Standby
Control Station(CS): 1
Software: Total Efficiency Pack, unless specified
Services: All default including migration
Education: Default / / For Latam Cases - No default, unless specified
Hw Maintenance: 36 months premium system default
Sw Maintenance: 36 months premium in sold, , unless specified
VNX1 Upgrade Config Default Steps (To fill existing)
RACK: EMC Rack // For Latam Cases - Customer Rack, unless specified
System: Unified // For Latam Cases - Block Only, unless specified
Vault/Base & Data Drive : Small drive type with lowest rpm to fill existing with total 15 drives i.e. 1st DAE fill. Take 15 drives including both Vault/Base & Data Drives for existing.
Data Mover(DM): 2 - 1 for primary & 1 for Standby
Control Station(CS): 1
Software: No need to fill existing
Services: Check process update section
Education: No
Hw Maintenance: Co-term
Sw Maintenance: 12 months premium in sold, , unless specified
VNX2 Upgrade Config Default Steps (To fill existing)
RACK: EMC Rack // For Latam Cases - Customer Rack, unless specified
System: Unified // For Latam Cases - Block Only, unless specified
Vault/Base & Data Drive : Small drive type with lowest rpm to fill existing with total 25 drives i.e. 1st DAE fill. Take 25 drives including both Vault/Base & Data Drives for existing.
Data Mover(DM): 2 - 1 for primary & 1 for Standby
Control Station(CS): 1
Software: No need to fill existing
Services: Check process update section
Education: No
Hw Maintenance: Co-term
Sw Maintenance: 12 months premium in sold, , unless specified
Mail Summary:
VNX2 NEW Models
VNX5400/5600/5800/7600/8000 Unified/Block Only/File Only <complete config name>:
VNX5200 Unified/Block Only/File Only <complete config name>:
Total Usable Capacity = XXTB Capacity Usable
Hardware
EMC Rack / EMC Dense Rack/ Customer Supplied Rack
Power Cords
Unified / Block Only / File Only
XX Data Movers, Copper Ports (Primary / Standby)
2 x 4 Port 1GB DM Modules = 8 Ports
1 x 4 Port 8GB FC Module Pair = 8 Ports
X x DAEs (Includes DPE) 2.5"/3.5"
X x RPAs Physical/Virtual
Drives:
Vault: X00GB 10K/15k 2.5" / 3.5" SAS Drives
X x X00GB Flash RX(X+X) 2.5" / 3.5" + X Hot Spare = XXTB Usable Capacity
X x X00GB 10K/15K SAS RX(X+X) 2.5" / 3.5" + X Hot Spares = XXTB Usable Capacity
X x XTB NL SAS RX(X+X) 2.5" / 3.5" + X Hot Spares = XXTB Usable Capacity
FAST Cache:
X x X00GB 2.5" / 3.5" FAST Cache drives = X00GB FAST Cache
X x X00GB 2.5" / 3.5" Drives – for FAST Cache Capacity
X x X00GB 2.5" / 3.5" Drives – for Mirror Protection
X x X00GB 2.5" / 3.5" Drives – for Hot Spare
Software
Unisphere, Total Efficiency Pack, Total Protection Pack, Local Protection Suite, Remote Protection Suite, Fast Suite, Application Protection Suite, Events and Retention Suite, ViPR SRM, Cloud Tiering Appliance Software, ItemPoint, PowerPath Software, Storage Analytics Suite
Services and Maintenance
Default Basic Services / No Services **
Default Customer Education / No Customer Education
HW Maintenance: 36 months default, XX months prepaid/concession (Premium / Enhanced)
SW Maintenance: 36 Months (Premium / Enhanced)
VNX / VNX2 Upgrades
Total Upgrade Capacity = XXTB Usable Capacity Upgrade
Hardware:
Rack with Power Cords (nothing if Customer Rack selected)
X x Data Movers Upgrade
X x X Port XGB DM Modules
X x X Port XGB FC/iSCSI/FCoE Module Pair Upgrade
X x DAEs 2.5"/3.5"
Drives:
X x X00GB Flash RX(X+X) 2.5" / 3.5" + X Hot Spare = XXTB Usable Capacity
X x X00GB 10K/15K SAS RX(X+X) 2.5" / 3.5" + X Hot Spares = XXTB Usable Capacity
X x XTB NL SAS RX(X+X) 2.5" / 3.5" + X Hot Spares = XXTB Usable Capacity
FAST Cache:
X x X00GB 2.5" / 3.5" FAST Cache Drives = XXTB FAST Cache
X x X00GB 2.5" / 3.5" Drives – for FAST Cache
X x X00GB 2.5" / 3.5" Drives – for Mirror Protection
X x X00GB 2.5"/ 3.5" Drives – for Hot Spare
X x RPAs Physical/Virtual
Software:
FAST Suite, Security & Compliance Suite(VNX-1) , Events and Retention Suite(VNX-2), Local Protection Suite, Remote Protection Suite, Application Protection Suite, Total Protection Pack, Total Efficiency Pack, Storage Analytics Suite, XtremCache and XtremSF, ViPR SRM, Cloud Tiering Appliance Software, ItemPoint, PowerPath Software
Services and Maintenance
Default Basic Services / No Services
No Customer Education
SW Maintenance: XX Months (Premium / Enhanced)
Default Notes
VNX5200 Unified/Block Only/File Only <complete config name>:
Total Usable Capacity = XXTB Capacity Usable
Hardware
EMC Rack / EMC Dense Rack/ Customer Supplied Rack
Power Cords
Unified / Block Only / File Only
XX Data Movers, Copper Ports (Primary / Standby)
2 x 4 Port 1GB DM Modules = 8 Ports
1 x 4 Port 8GB FC Module Pair = 8 Ports
X x DAEs (Includes DPE) 2.5"/3.5"
X x RPAs Physical/Virtual
Drives:
Vault: X00GB 10K/15k 2.5" / 3.5" SAS Drives
X x X00GB Flash RX(X+X) 2.5" / 3.5" + X Hot Spare = XXTB Usable Capacity
X x X00GB 10K/15K SAS RX(X+X) 2.5" / 3.5" + X Hot Spares = XXTB Usable Capacity
X x XTB NL SAS RX(X+X) 2.5" / 3.5" + X Hot Spares = XXTB Usable Capacity
FAST Cache:
X x X00GB 2.5" / 3.5" FAST Cache drives = X00GB FAST Cache
X x X00GB 2.5" / 3.5" Drives – for FAST Cache Capacity
X x X00GB 2.5" / 3.5" Drives – for Mirror Protection
X x X00GB 2.5" / 3.5" Drives – for Hot Spare
Software
Unisphere, Total Efficiency Pack, Total Protection Pack, Local Protection Suite, Remote Protection Suite, Fast Suite, Application Protection Suite, Events and Retention Suite, ViPR SRM, Cloud Tiering Appliance Software, ItemPoint, PowerPath Software, Storage Analytics Suite
Services and Maintenance
Default Basic Services / No Services **
Default Customer Education / No Customer Education
HW Maintenance: 36 months default, XX months prepaid/concession (Premium / Enhanced)
SW Maintenance: 36 Months (Premium / Enhanced)
VNX / VNX2 Upgrades
Total Upgrade Capacity = XXTB Usable Capacity Upgrade
Hardware:
Rack with Power Cords (nothing if Customer Rack selected)
X x Data Movers Upgrade
X x X Port XGB DM Modules
X x X Port XGB FC/iSCSI/FCoE Module Pair Upgrade
X x DAEs 2.5"/3.5"
Drives:
X x X00GB Flash RX(X+X) 2.5" / 3.5" + X Hot Spare = XXTB Usable Capacity
X x X00GB 10K/15K SAS RX(X+X) 2.5" / 3.5" + X Hot Spares = XXTB Usable Capacity
X x XTB NL SAS RX(X+X) 2.5" / 3.5" + X Hot Spares = XXTB Usable Capacity
FAST Cache:
X x X00GB 2.5" / 3.5" FAST Cache Drives = XXTB FAST Cache
X x X00GB 2.5" / 3.5" Drives – for FAST Cache
X x X00GB 2.5" / 3.5" Drives – for Mirror Protection
X x X00GB 2.5"/ 3.5" Drives – for Hot Spare
X x RPAs Physical/Virtual
Software:
FAST Suite, Security & Compliance Suite(VNX-1) , Events and Retention Suite(VNX-2), Local Protection Suite, Remote Protection Suite, Application Protection Suite, Total Protection Pack, Total Efficiency Pack, Storage Analytics Suite, XtremCache and XtremSF, ViPR SRM, Cloud Tiering Appliance Software, ItemPoint, PowerPath Software
Services and Maintenance
Default Basic Services / No Services
No Customer Education
SW Maintenance: XX Months (Premium / Enhanced)
Default Notes
VNX (If SN is provided)
SYR
does not contain the current config details for VNX. The Install Base (IB)
feature in MyQuotes has shown to be un-reliable. For this reason, we have made
an assumption that rack space is available for the upgrade configuration. We
have built the config to include the proper data drives, spares, and DAEs to
fulfill the request, and rack space should be verified.
VNX
(If SN is not provided:)
Please
note that we have assumed that rack space is available for the upgrade
configuration. We have built the config to include the proper data drives,
spares, and DAEs to fulfill the request, and rack space should be verified.
VNX
Budgetary Estimate
Please
note that for all upgrades, SN is required to be provided in MyQuotes if you
need to submit the order. I have added an exception as ‘Budgetary Estimated
Only’ for now.
Software upgrade
In VNX software upgrades, existing drive
count does not impact the quantity/model/price of software licenses added. IB
data information has shown to be unreliable. To complete the configuration in
MyQuotes, we have assumed one DAE fully populated as
existing. However if you need existing array details to be populated correctly,
please provide us with current drive information or SP collects.
VNX
RAID
The
EMC best practices on VNX suggest using Raid 6 (6+2 default) for 1 TB and
larger NL-SAS drives. VNX EFD and SAS drives will use RAID5 (4+1) unless
otherwise specified in the sizing request or to meet the workload requirements.
These RAID choices provide the best possible combination of performance and
capacity and also help the overall reliability of the solution.
Capacity
mis-match
Due
to raid constraints I was not able to match exact requested capacity. So I have
configured the next possible capacity to satisfy the request.
Hot Spare
i have taken requested drives as Data drives including hot spares.
Hot Spare
i have taken requested drives as Data drives including hot spares.
Co-term
Hardware Maintenance
The
HW maintenance cost is included with the upgrade part numbers. The maintenance
period will be co-terminus with the existing.
No comments:
Post a Comment
Thank You.........For Your Feedbak