Default Notes
Customer Account No.
Please verify Customer Account used. Let
me know if needs to be changed.
NO
CUSTOMER INFORMATION GIVEN NOTE
As no customer information has been
provided in the request, I have created the quote using EMC
dummy customer name as
the Customer. Please verify and let me know if it needs to be altered.
VNX
(Serial No. is provided)
SYR does not contain the current config
details for VNX. The Install Base (IB) feature in MyQuotes has shown to be
un-reliable. For this reason, we have made an assumption that rack space is
available for the upgrade configuration. We have built the config to include
the proper data drives, spares, and DAEs to fulfill the request, and rack space
should be verified.
(Serial No. not provided)
Please note that we have assumed that
rack space is available for the upgrade configuration. We have built the config
to include the proper data drives, spares, and DAEs to fulfill the request, and
rack space should be verified.
(Raid)
The
EMC best practices on VNX suggest using Raid 6 (6+2 default) for 1 TB and
larger NL-SAS drives. VNX EFD and SAS drives will use RAID5 (4+1) unless
otherwise specified in the sizing request or to meet the workload requirements.
These RAID choices provide the best possible combination of performance and
capacity and also help the overall reliability of the solution.
(Software upgrade)
In VNX software upgrades, existing drive
count does not impact the quantity/model/price of software licenses added. IB
data information has shown to be unreliable. To complete the configuration in
MyQuotes, we have assumed one DAE fully populated (vault + 11 drives) as
existing. However if you need existing array details to be populated correctly,
please provide us with current drive information or SP collects.
VNXe
VAULT Drive Request
In VNXe Models, Vault is in-built in the
form of flash memory and it cannot be altered.
Budgetary
Estimate Note
Please note that for all upgrades, SN is
required to be provided in MyQuotes if you need to submit the order. I have
added an exception as ‘Budgetary
Estimate Only’
for now.
VMAX
(Raid)
The EMC best practices for FAST VP on
Symmetrix suggest using RAID5 3+1 for the EFD tier, RAID 1 for the FC tier, and
RAID6 6+2 for the SATA tier. These RAID choices provide the best possible
combination of performance and capacity and also help the overall reliability
of the solution.
For Symmetrix upgrades when SN is
provided use the following when there is no SW information provided in the
request.
SYR reports software installed in the
entire site and it is not possible to tell what is installed in the current
box. So I have not assumed any SW as existing. Please let me know what are the
existing SW installed in this array so that I can update the quote to get the
necessary Tier upgrades.
(Promo pack discount)
Since EFD drives are configured , So
promo pack is going by default with the configuration. Hence i have configured
recommended discount for those drives.
(Co-Term)
The HW maintenance cost is included with
the upgrade part numbers. The maintenance period will be co-terminus with the
existing.
(Dare)
Symmetrix Data at Rest Encryption
is recommended for security. If required, it must be added now and cannot be
selected at a later date. Kindly let me know if it is required.
VMAX
10K UPGRADE NOTES
SYR reports software installed in the
entire site and it is not possible to tell what is installed in the current
box. So I have not assumed any SW as existing except for Symm
Management Suite
to satisfy the configuration. Please let me know what is the existing SW
installed in this array so that I can update the quote to get the necessary
Tier upgrades.
Please note that 1TB of Capacity Upgrade
License gets triggered by the configurator for every Software Upgrade in VMAX
10K and we do not have an option to remove that.
The HW maintenance cost is included with
the upgrade part numbers. The maintenance period will be co-terminus with the
existing.
ViPR
SRM PS NOTE
I have configured the ViPR SRM Solution
for Isilon nodes with only 1 x PS-BAS-SRMSIMP
(STANDARD IMPLEMENTATION FOR VIPR SRM) in ViPR SRM Solution for Isilon S210
Nodes as triggered by the configurator which can take care of ViPR SRM
installation for up to 3 Data Centers and 25 Arrays. Please let me know if it
needs to be altered.